Applications - Microbiological control in hospitals - Clean production areas - Clean research areas - Pharmaceutical laboratories All systems come complete with filters, owners manual, 6 foot power cord, and certificate of guaranteed performance. |
![]() |
HEPA Filter replace every 1-2 yrs Pre-Filter replace every 6-18 months Pre-Filter replace every 6-18 months |
All systems come complete with filters, owners manual, 6 foot power cord, and certificate of guaranteed performance. Optional casters ( Mobility 56 ) sold separately.
Rated #1 by: |
![]() |
||||
| |||||
Ultra-Quiet Design | |||||
With its large fan motor, IQAir® systems produce more clean air with less noise than conventional air cleaners. Unlike most air cleaners, which have the fan motor located after all filter stages, IQAir® systems have the fan in the center, in-between its noise absorbing filters. IQAir® systems also feature a unique double-walled housing design to reduce sound transmission. Eight shock absorbers, which hold the fan ensure that vibration isn't transmitted to the housing. The results are impressive. IQAir® systems are suitable for even the most noise sensitive environments and are virtually inaudible at the lowest fan speed setting. | |||||
Advanced Controls | |||||
Intelligent Filter Life Monitor Ordinary air cleaners have you guess when to replace filters or use a preset timer. IQAir's intelligent filter life monitor takes actual use, speed settings and air quality conditions into account. This ensures maximum filter yield and performance from your IQAir system.
Up to Six Fan Speed Settings Most air cleaners provide only two or three fan speed settings. You have to run the unit either on a quiet but ineffective fan speed, or choose a more powerful, but noisy speed. IQAir systems give you the choice of up to six fan speeds, allowing you to select the ideal performance-to-sound ratio. Integrated Timer ![]() Remote Control Selected IQAir® systems come with a remote control which allows you to turn the unit on and off, select the fan speed and activate the timer. | |||||
Certified Performance | |||||
![]() | |||||
Easy Filter Replacement | |||||
IQAir® systems feature a revolutionary modular tower design, which
snaps open to allow access to all filters in a matter of seconds. ![]() | |||||
Long Filter Life | |||||
![]() The filters in IQAir® systems are designed to last longer than those in conventional air cleaners. High-Efficiency Pre-Filtration While most air cleaners use pre-filters with particle efficiencies well below 20%, IQAir® systems typically retain over 90% of particle mass in the pre-filter. As a result, IQAir's HEPA and gas phase filter are better protected from premature loading. Independent Filter Stages Conventional air cleaners often combine several filter types in one filter cartridge. As a result, the whole cartridge has to be replaced even if only one filter type is used up. Large Filters To minimize manufacturing cost, most air cleaners use very little filter material. IQAir uses commercial size filters that are able to collect more pollutants and last longer. | |||||
Triple Seal Design | |||||
![]() IQAir systems feature patented triple sealing technology. First, a unique process ensures that the filter media is 100% sealed in the filter frame. Second, our patented 3D UltraSeal ensures perfect sealing between filter frame and housing. Third, individual seals on each housing module ensure an air tight housing. As a result, IQAir® systems have an actual system efficiency which is higher than the theoretical efficiency of conventional air cleaners. | |||||
High-Quality Fan | |||||
![]() | |||||
No-Draft Design | |||||
![]() | |||||
Energy Efficient | |||||
Even though IQAir® systems are very powerful, they are also energy efficient. Outstanding energy efficiency is achieved with a very efficient fan and an advanced fan control setup. As a result, it cost only pennies per day to run an IQAir® system. | |||||
Tough Construction | |||||
Many high-end air cleaners are made from sheet metal which dents easily and where the paint scratches and chips. Many department store air cleaners use inferior plastics which shatter easily. Built to last and look great for a lifetime, IQAir systems are manufactured from fully cured, high-grade injection molded ABS. A 3 mm (0.125 inch) housing thickness makes IQAir systems extremely impact resistant. | |||||
Long Warranty | |||||
All IQAir® systems are covered by a one or five year warranty depending on model and country of purchase. Filters, as consumables, are exempt from this warranty. |
Specifications-Cleanroom H13 | Other Information |
![]() 1. User Control Panel 2. Carrying Handle 3. No-Draft Diffuser 4. Cleanroom-Grade HyperHEPA Filter 5. Snap-Open Locking Arms 6. High-Performance Centrifugal Fan 7. Advanced Fan Control 8. Pre-Max Pre-Filter (Class F8) 9. Dual Floor Air Intake |
Professional Control Airborne
Particulates
The IQAir® Cleanroom Series has been designed specifically for the removal of airborne particles. The systems feature the highest air delivery and longest filter life of any IQAir particle filter system. To allow for maximum air delivery the systems contain no gas phase filtration. The Cleanroom Series provides a choice of 2 models, each with a specific filter efficiency and air delivery profile. While healthcare facilities may require higher air delivery to achieve optimum control of microorganisms (e.g. in ICUs or TB isolation rooms), a cleanroom facility may need a filtration efficiency of 99.97% to meet strict manufacturing regulations or standards. Positive and Negative Pressure EnvironmentsEach IQAir® Cleanroom system can be used as a recirculation device or it can be combined with IQAir's ducting adapters InFlow W125 or OutFlow W125 to create positive and negative pressure environments. The creation of negative pressure helps to contain harmful particles, such as microorganisms, in a particular area (e.g. TB isolation). The creation of positive pressure helps to protect clean areas from contaminants entering from adjacent rooms (e.g. protective isolation of immuno-compromised patients, controlled environments for medical device manufacturing). Decentralised Airborne Infection Control in Health-Care FacilitiesAirborne pathogens in health-care environments pose a particular risk to immunocompromised patients who may inhale fungal spores, bacteria and viruses. Airborne microorganisms can not only complicate recovery from surgery, but can also lead to life-threatening infections,costing health-care services hundreds of millions every year. Hospital-acquired aspergillosis for example has been recognised increasingly as a cause of severe illness and high mortality in immunocompromised individuals, e.g. patients undergoing chemotherapy and/or organ or bone marrow transplants. In the light of the marked increase in nosocomial infections over recent years, many of which are caused by drug-resistant pathogens, the importance of using high-efficiency air filtration systems beyond the confines of so-called ¡°critical areas¡± (such as operation theatres) has once again been emphasised. Both the World Health Organisation (WHO) and the Centers for Disease Control and Prevention (CDC), advise that, wherever possible, preventive infection control measures should be implemented to reduce the risk of nosocomial infections. For more critical control of gaseous compounds see GC Series models. |
General Specifications- Cleanroom H13 | |
Number of Selectable Fan Speeds | 5 |
Air Delivery (with new filters installed) per Speed | 1 - 45 cfm 2 - 70 cfm 3 - 90 cfm 4 - 155 cfm 5 - 270 cfm |
Maximum Coverage Area | 1200 sq ft (based on maximum fan speed and an 8.5 ft ceiling) |
System Efficiency for Particles |
99.99% or more at 0.3 microns |
Power Requirements | 115 VAC 50-60 Hz The entire electrical system is UL certified. |
Energy Consumption (Max) | 195 W |
Standby Energy Consumption | 2.5 W |
Power Cable | Detachable 6 foot |
Dimensions | H 32" W 15" D 16" |
Net Weight (including filters) | 33 lbs |
Warranty Period | 1 yr on unit including fan motor, excluding filters |
Filters | |
Number of Filter Stages | 2 (fine dust and micro dust filtration) |
Total Number of Replacement Filters | 2 (pre-filter, HEPA Filter) |
Pre-Filter | 32 sq ft mini-pleat fine dust filter |
HEPA Filter Efficiency | 99.97% at .3 microns |
HEPA Filter Surface Area | 44 sq ft. |
Filter Frame Material | Expanded polystyrene (EPS), chlorofluorocarbon (CFC) - free |
Filter Life | Pre-Filter 6-18 months HEPA up to 2 years (filter life is dependant on the operating environment) |
Housing | |
Number of Housing Modules | 6 |
Housing Material | PC-ABS and ABS(UV-stabilized) |
Color of Main Housing/Arms | Light Gray/White |
Air Intake | Two side openings at base of unit |
Air Outlet | Via diffuser with horizontal 320 degree opening on top of unit |
Fan | |
Fan Type | Centrifugal fan, backward curved, single inlet |
Bearings | Maintenance-free steal ball bearings |
Speed Regulation | Voltage reductions via capacitor switching |
Electronic Control Panel | |
Control Panel Finish | Polyester overlay panel |
Main Display | Liquid crystal display, 16 character x 2 line |
Status and Indicator LEDs | Timer Status LED, Filter Life Status LEDs, Fan Speed Indicator LEDs |
Display Languages | English, French, German, Italian, Spanish |